DC Input
|
48VDC (40 - 63V)
|
|
Efficiency
|
80% typical
|
|
Inrush Current Limiting
|
The turn-on in-rush current will not
exceed 20 amps peak.
|
|
EMI
|
Conducted EMI conforms to VDE 0871,
level B 10kHz-30MHz. FCC Part 15 Subpart J Class B.
EN55022 and BS6527 Level B VDE 0871, Level B
10kHzl1000MHz. Radiated EMI conforms to VDE 0871,
Level B 10kHz-1000MHz.
|
|
DC Output
|
Voltage range shown in table.
|
|
Output Power
|
300 watts max (1m/sec air flow or
integral fan option required), 200 watts max on
convection cooled models.
|
|
Line Regulation
|
±0.2% on main and auxiliary outputs
for ±1% on main output; 2% for load changes from
20-100% an auxiliary required on main output of WD300.
|
|
Load Regulation
|
±1% on main output; 2% for load
changes from 20-100% an auxiliary outputs. Minimum
load of 5A required on main output.
|
|
Ripple and Noise
|
50mv pk-pk on main outpt; 1% pk-pk
on auxiliary outputs. 10Hz-30MHz bandwidth.
|
|
Hold-up Time
|
Á500 usec, input nom Vac.
|
|
Overvoltage Protection
|
Overvoltage protection is provided
on the main 5 volt output only.
|
|
Overload Protection
|
A automatic electronic current
limiting circuit, limits the output current to a
preset value, thereby providing protection for the
load as well as the power supply.
|
|
Cooling
|
The WD305 is convection cooled and
is available with an optional fan.
|
|
Operating Temperature Range
|
0 to +70° with linear derating from
+50 to +70C. Derate to 50% power at +70°C.
|
|
Temperature Coefficient
|
0.02% /°C on main output. 0.95% /°C
on auxiliary outputs.
|
|
Isolation
|
Type tested 1 minute without
breakdown, "Y capacitors removed. Input to ground
& input to output: 4KV RMS 50Hz. Output common to
ground: 700 VDC. production tests on complete units, 1
minute without breakdown. Input to grounded outputs:
1.6KV RMS 50Hz. Outputs to ground: 700VDC. Input to
output resistance: > 100M ° at 500VDC.
|
|
Remote Sensing
|
Available on main output for voltage
drops of 0.5V max.
|
|
Safety Agency Approval
|
BS6301, BS7002, IEC950, UL950,
EN60950, CSA234 Level 6, VDE0805.
|
|
Options
|
Output power good, low battery
alarm, overtemperature cutout remote on/off, integral
fan, and current share (main output only).
|
|
Warranty
|