UltraFlex(DC) Series

48 VDC-input modular power supplies

Product Data | Models | Specifications | Similar Series

There's no need to panic just because you need a power supply that doesn't seem to be available from stock. In just one week or less, Lambda will ship a prototype 600W DC input supply with any output voltages and signals you need.

With leading edge and proprietary circuit design, 280 KHz fixed frequency converters, synchronized circuits, planar magnetics, advanced thermal management and surface mount technology, these power supplies offer state-of-the-art power densities, exceptional flexibility, reliability, and outstanding performance.

Lambda's UltraFlex Series gives you the flexibility you need to cope with today's fast paced new product development cycles and relentless time-to-market schedules.

UltraFlex(DC) Series

 

 CE CSA  UL  TUV

   

Customized Power Supplies

Up to 10 Outputs

Universal AC Input or
48VDC Input

Compact Packages

Fully Regulated &
Independent Outputs

System Interface &
Monitoring Signals

International Safety
Agency Approvals

Conducted EMI B

Input Transient Protection

   

UltraFlex(DC) Series Available Models <

 

Sample Configurations

 

Output 1
Output 2
Output 3
Output 4
Output 5

V
A
V
A
V
A
V
A
V
A

UCZ4-T

48
8
-
-
-
-
-
-
-
-

UCZ4-DH

3.3
30
5
60

UCZ4-GJJ

5
30
12
17
12
17

UCZ4-HY

5
60
12
10
12
4

UCZ4-HJJP

5
55
12
17
12
17
24
8.5

UCZ4-HKW

5
55
12
30
5
8
12
3

UCZ4-HWY

5
55
5
8
12
3
12
8
12
3

UCZ4-GGJJP

5
30
5
30
12
17
12
17
24
8.5

Part Number Format

 
UC

Z

4
-
G
G
J
J
P

Case Code

Option Code

EMI Code

Output Module Code(s)

Configuration Guidelines

1) Case Codes

Depending on your input voltage & power needs choose from the following converters:

 
Code
Power
Input
EMI ( Conducted )
Dimensions
Note
UC
600 Watts
36 - 75 VDC
Class B
2.5" x 5" x 12"

 

2) Options Codes

Available options for the converters are as follows:

 

Code

Description

Applicable Converters

Z

Output & Input Signals

UC


Output Signals:

Active Current Share, Output Good, Module Inhibit, Remote Adjust Margin and Current Monitor

Input Signals:

Input Power Fail, Global Inhibit, Fan Inhibit, Fan Stop, Thermal Alarm, 5V standby

3) EMI Codes

Match the EMI code to the corresponding converter

 
Code
Converter
Power
Input
EMI ( Conducted )
4
UC
600 Watts
36 - 75 VDC
Class B

4) Output Module Code Selections

From the table below match the available modules to your voltage and current requirements. Modules are available in different power levels which corresponds to varying slot widths. The maximum total of slots for each converter is 5 Slots.

 

Code
V1 nom
Amps3
V2 nom
Amps
V1 adjust
V2 adjust
Slot(s)1

Single Output

A
2.0
30.0
-
-
1.8 - 2.2
-
1

B
2.0
60.0
-
-
1.8 - 2.2
-
2

C
2.0
90.0
-
-
1.8 - 2.2
-
3

D
3.3
30.0
-
-
3.0 - 3.6
-
1

E
3.3
60.0
-
-
3.0 - 3.6
-
2

F
3.3
90.0
-
-
3.0 - 3.6
-
3

G
5.0
30.0
-
-
4.5 - 6.0
-
1

H
5.0
60.03
-
-
4.5 - 6.0
-
2

I
5.0
90.0
-
-
4.5 - 6.0
-
3

J
12.0
17.0
-
-
10.8 - 13.2
-
1

K
12.0
30.0
-
-
10.8 - 13.2
-
2

L
12.0
50.0
-
-
10.8 - 13.2
-
3

M
15.0
14.0
-
-
13.5 - 16.5
-
1

N
15.0
24.0
-
-
13.5 - 16.5
-
2

P
24.0
8.5
-
-
21.6 - 26.4
-
1

Q
24.0
15.0
-
-
21.6 - 26.4
-
2

R
24.0
25.0
-
-
21.6 - 26.4
-
3

8
28.0
12.0
-
-
25.2 - 30.8
-
2

3
36.0
11.0
-
-
32.4 - 39.6
-
2

S
48.0
4.0
-
-
43.2 - 52.8
-
1

T
48.0
8.0
-
-
43.2 - 52.8
-
2

U
48.0
12.5
-
-
43.2 - 52.8
-
3

Dual Output

V
5
43
12
103
4.5 -5.5
10.8 - 13.2
1

W
5
103
12
4
4.5 -5.5
10.8 - 13.2
1

Y
12
103
12
43
10.8 - 13.2
10.8 - 13.2
1

Z
15
10
15
4
13.5 - 16.5
13.5 - 16.5
1
Notes:
      1) The total # of slots must not exceed 5
      2) Module codes are ordered numericaly then alphabetically.
          (i.e. UCZ4-38G or UCZ4-3GPS)
      3) Module Deratings when using 600 watt converters (UC):
             H derates to 55A
             V, W & Y: 10A derates to 8A & 4A derates to 3A.
             Peak currents for 1 minute without derating.

 

UltraFlex(DC) Series Specifications

 

DC Input

36-75VDC on Case C.

Efficiency

75% typical at nominal line voltage.

Inrush Current Limiting

Less than 40amps peak.

EMI

Conducted EMI conforms to EN55022, Level B, and FCC Docket 20780 Part 15, Subpart J, Class B.

Output Voltage Adj Range

±10% of nominal output voltage on all.

Line Regulation

Less than 0.1% for line variations from 85-265VAC. Less than 0.2% for dual output modules.

Load Regulation

Less than 0.4% for load variations from no load to full load and full load to no load. Less than 0.8% for dual output modules.

Cross Regulation

Less than 0.1% between single output modules. Less than 3% between dual outputs with 25% load change on high current output.

Ripple and Noise

For outputs 12V or less, 50mV pk to pk or 15mV RMS. For outputs greater than 12V, 1% pk to pk or .33% V RMS. For dual outputs, 1% pk to pk or .33% V RMS 20mHz bandwidth.

Preload

External preload is not required on single output modules. Dual output modules require 1A minimum load on the highest current output (Output #1).

Hold-up Time

The output voltage will remain within regulation limits for 20msec at full load with nominal 115/230VAC line input.

Overvoltage Protection

Internal circuitry will shut down the individual output module. Reset the OVP by recycling the input power.

Overload Protection

Overcurrent protection on single output modules limits the current. Upon removal of the overload condition, normal operation resumes automatically.

Cooling

Cooling is provided via an internal DC operated ball-bearing fan.

Operating Temperature Range

Full operation from 0° to +50°C with 100% rated power on most models. Derate linearly from +50°C to 50% power at +65°C.

Storage Temperature

-40°C to +85°C.

Temperature Coefficient

0.02%/ °C.

Isolation

Conforms to safety agency requirements.

Remote Sensing

Remote sense compensates for total cable drop of up to 0.5VDC. Available on all outputs.

Thermal Protection

The power supply will shut down in the event of an overtemperature condition (the fan will continue to operate). To restore operation, the supply must cool down and the AC input must be recycled.

Mounting

Two mounting surfaces on all models.

Military Specifications

SHOCK - MIL-STD-810E, Method 516.4,Procedure 1. VIBRATION - MIL-STD-810E, Method 514.4,Category I, TP1.

Safety Agency Approval

UL 1950, CSA 22.2 No.220 and/or 234 Bulletin 1902A, EN 60950, EN 41003 & BS 7002, CE (Low Voltage Directive).

Warranty

3 years.

 

 