DLP Series FAQ
1. Question: What do the two LEDs on the front of the DLP indicate?
Answer:
| |
Normal operation |
Overcurrent |
Short circuit Load |
Overvoltage |
| Green LED (DC ON) |
ON |
ON |
OFF |
OFF |
| Red LED (ALM) |
OFF |
ON |
ON |
OFF |
The red LED operates when the output voltage drops below 20V (approximately)
2. Question: What is the switching frequency of the DLP series?
Answer:
DLP75: 60kHz to 400kHz, DLP100, 120: 140kHz, DLP180: 110kHz, DLP240: 95kHz
Return to Product Page
|